Goodman 1.5 Ton 14 SEER2 60000 BTU 96% AFUE Two Stage Multi-Speed ECM Gas Furnace System - Upflow | R32
-
Condenser
1 × Goodman 1.5 Ton 13.4 SEER2 R32 Cooling Only Condenser (GLXS3BN1810)
$1,681.27$1,450.10$1,681.27$1,450.10 -
Gas Furnace
1 × Goodman R32 60000 BTU 96% Two-Stage Multi-Speed ECM Gas Furnace Upflow / Horizontal ( GR9T960603AN)
$2,057.74$1,774.81$2,057.74$1,774.81 -
Evaporator Coil
1 × Goodman 2 Ton R32 Evaporator Coil With Internal TXV Upflow / Downflow (CAPTA2422A3)
$771.02$665.00$771.02$665.00
We highly recommend this protection. Covers the technician’s bill if a repair is ever needed — parts are already covered separately.
-
0% Interest — for orders over $3000
-
No Credit Needed — Offered at checkout
-
7 night Luxury Resort Stay — For orders over $3000
What's Included
What's Included
Goodman 1.5 Ton 13.4 SEER2 R32 Cooling Only Condenser
Model Number
GLXS3BN1810
Dimensions
26" W x 26" D x 27-1/2" H
Documents
Warranty
Parts: 10 years
Goodman R32 60000 BTU 96% Multi-Speed ECM Furnace Upflow / Horizontal
Model Number
GR9T960603AN
Dimensions
14" X 28-3/4" x 34-1/2" H
Documents
Limited Warranty
Heat Exchanger: Limited Lifetime | Parts: 10 years
Goodman 2 Ton R32 Evaporator Coil With Internal TXV Upflow / Downflow
Model Number
CAPTA2422A3
Dimensions
14" W x 21" D x 22" H
Documents
Warranty
Parts: 10 years
AHRI Number
215276821
Outdoor Unit Details
Outdoor Unit Details
GLXS3B Overview
Product Benefits:
- Energy-Efficienct Compressor
- Fully charged for 15' of tubing length
- Copper tube/ enhanced aluminum fin coil-5mm diameter
- Factory-installed filter drier
- Sweat connection service valves with easy access to gauge ports
- Enclosed contactor with lug connection
- High-pressure switch
- Capacitors with extended life
- AHRI Certified
- ETL Listed
Cabinet Features:
- Removable grille-style top design compliant with UL 60335-2-40
- Venturi for increased velocity of airflow
- Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
- Wire fan discharge grille
- Steel louver coil guard
- Top and side maintenance access
- Single-panel access to controls with space provided for field-installed accessories
- When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
Indoor Unit Details
Indoor Unit Details
GR9T96 Overview
Standard Features
- Energy-efficient, multi-speed ECM blower motor
- Heavy-duty, aluminized-steel tubular heat exchanger
- Stainless-steel secondary heat exchanger
- Two-stage gas valve provides quiet, economical heating
- Durable Silicon Nitride igniter
- Quiet two-speed induced draft blower
- Self-diagnostic control board with constant memory fault code history output to a LED
- Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier
- Low continuous fan speed options offer quiet air circulation
- All models comply with California 40 ng/J Low NOx emissions standard
- Can not be installed in California’s South Coast AirQuality Management District (SCAQMD) and San Joaquin Valley Air Pollution Control District (SJVAPCD).
- AHRI Certified; ETL Listed
Cabinet Features
- Designed for multi-position installation —
- GR9T96: upflow, horizontal left or right
- GD9T96: downflow, horizontal left or right
- Certified for direct vent (2-pipe) or non-direct vent (1-pipe)
- Easy-to-install top venting with optional side venting — GR9T96/upflow models only
- Convenient left or right connection for gas and electrical service
- Cabinet air leakage (QLeak) ≤ 2%
- Heavy-gauge steel cabinet with durable finish
- Fully insulated heat exchanger and blower section
- Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications
CAPTA Overview
Standard Features
- All-Aluminum evaporator coil
- Optimized for use with R-32 refrigerant including circuits and manifolds
- R-32 sensor designed for the life span of the coil
- CAPTA and CHPTA models feature factoryinstalled thermal expansion valves for cooling and heat pump applications
- Standardized copper suction tube stub length
- Vertical and horizontal models available
- 21" depth for easier attic access
- CAPTA and CHPTA models include a single front access panel
- Foil-faced insulation covers the internal casing to reduce cabinet condensation
- Galvanized, leather grain-embossed finish
- Rust resistant, thermoplastic drain pans featuring a low water-retention design
- DecaBDE-free thermoplastic drain pan with secondary drain connections
- Drain pan rails designed to remove and reposition coils with ease without compromising structural integrity
- UV-resistant drain pan
- AHRI certified; ETL listed
Note: Do not use these coils on oil furnaces or any applications where the temperature on the drain pan may exceed 300° F. If these coils are applied with an oil furnace or another application where high temperatures threaten or jeopardize the durability of the drain pan, you must replace the factory-installed drain pan with a high-temperature drain pan. High-temperature drain pan kits are available as field-installed accessories.
Shipping & Returns
Shipping & Returns
Fast nationwide fulfillment from the USA. Free shipping on qualifying orders over $1,500. See our shipping and returns policy for full details.